Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6JXI

Rb+-bound E2-MgF state of the gastric proton pump (Tyr799Trp)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL41XU
Synchrotron siteSPring-8
BeamlineBL41XU
Temperature [K]80
Detector technologyPIXEL
Collection date2018-05-14
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0
Spacegroup nameP 31 2 1
Unit cell lengths103.380, 103.380, 369.860
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution47.670 - 2.600
R-factor0.2092
Rwork0.206
R-free0.26290
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5ylu
RMSD bond length0.009
RMSD bond angle1.209
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.13_2998)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.0002.700
High resolution limit [Å]2.6002.600
Number of reflections638312533
<I/σ(I)>16.191.16
Completeness [%]88.9
Redundancy8
CC(1/2)0.9900.700
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.529310% glycerol, 20% PEG2000MME, 0.4 M RbCl, 3% methylpentanediol, 5 mM beta-mercaptoethanol

223166

PDB entries from 2024-07-31