6IM9
MDM2 bound CueO-PM2 sensor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSRRC BEAMLINE BL13B1 |
Synchrotron site | NSRRC |
Beamline | BL13B1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-10-14 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 83.636, 83.636, 240.171 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 28.920 - 3.300 |
R-factor | 0.1801 |
Rwork | 0.177 |
R-free | 0.24930 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1KV7 and 5WTS |
RMSD bond length | 0.011 |
RMSD bond angle | 1.215 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | PHENIX (1.13_2998) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 30.000 | 30.000 | 3.380 |
High resolution limit [Å] | 3.300 | 8.090 | 3.300 |
Rmerge | 0.046 | 0.019 | 0.282 |
Rmeas | 0.052 | 0.021 | 0.326 |
Rpim | 0.023 | 0.009 | 0.159 |
Total number of observations | 77012 | ||
Number of reflections | 15209 | 1129 | 850 |
<I/σ(I)> | 14.1 | ||
Completeness [%] | 98.7 | 98.8 | 85.8 |
Redundancy | 5.1 | 4.8 | 3.4 |
CC(1/2) | 0.999 | 0.961 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 289 | 4M sodium formate |