Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6GU7

CDK1/Cks2 in complex with AZD5438

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-05-08
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.92819
Spacegroup nameP 1 21 1
Unit cell lengths67.995, 149.202, 87.260
Unit cell angles90.00, 92.23, 90.00
Refinement procedure
Resolution87.350 - 2.750
R-factor0.2292
Rwork0.227
R-free0.27370
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4yc6
RMSD bond length0.011
RMSD bond angle1.540
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]87.35087.350
High resolution limit [Å]2.7502.750
Rmerge0.0900.800
Number of reflections45022
<I/σ(I)>8.81.4
Completeness [%]99.899.5
Redundancy3.83.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP277CONDITIONS AROUND 0.1M TRIS/BICINE (PH8.5), 10% PEG8K, 20% ETHYLENE GLYCOL PROTEIN AT 10-12 MG/ML, 0.5mM INHIBITOR

226707