6EOR
DPP9 - 1G244
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-02-24 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.99997 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 119.357, 117.212, 163.396 |
Unit cell angles | 90.00, 105.57, 90.00 |
Refinement procedure
Resolution | 43.520 - 2.900 |
R-factor | 0.26852 |
Rwork | 0.265 |
R-free | 0.33173 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1orv |
RMSD bond length | 0.008 |
RMSD bond angle | 1.335 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.500 | 3.090 |
High resolution limit [Å] | 2.900 | 2.900 |
Number of reflections | 95096 | 16260 |
<I/σ(I)> | 9.5 | 4.98 |
Completeness [%] | 99.0 | 99.2 |
Redundancy | 4.28 | 4.38 |
CC(1/2) | 0.940 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 10% PEG 8000, 25% Glycerol, 0.16M Calcium Acetate, 0.08M Cacodilate pH 6.25 |