6CYT
HIV-1 TAR loop in complex with Tat:AFF4:P-TEFb
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.3.1 |
Synchrotron site | ALS |
Beamline | 8.3.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-10-11 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.11583 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 148.580, 148.580, 104.630 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 128.674 - 3.500 |
R-factor | 0.251 |
Rwork | 0.247 |
R-free | 0.28290 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5l1z |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHENIX |
Refinement software | PHENIX (1.13_2998) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 140.000 | 3.625 |
High resolution limit [Å] | 3.500 | 3.500 |
Number of reflections | 17145 | 1690 |
<I/σ(I)> | 11.1 | 0.63 |
Completeness [%] | 99.5 | 96.1 |
Redundancy | 37.6 | 16.3 |
CC(1/2) | 0.999 | 0.441 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 291 | 50 mM Tris 8.5, 0.2M Ammonium Acetate, 6 mM MgCl2, 8% PEG 4K |