Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6CYC

PDE2 in complex with compound 5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2013-08-02
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.000
Spacegroup nameP 21 21 21
Unit cell lengths72.250, 96.410, 101.650
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.170 - 1.540
R-factor0.186
Rwork0.185
R-free0.20500
RMSD bond length0.010
RMSD bond angle0.960
Data reduction softwareXDS
Data scaling softwareautoPROC
Phasing softwareREFMAC
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]38.1701.620
High resolution limit [Å]1.5401.540
Rmerge0.0700.680
Number of reflections105238
<I/σ(I)>13.4
Completeness [%]99.9100
Redundancy6.56.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29312% PEG8000, 0.1M Hepes pH7.5, 1mM TCEP

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon