Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-BM |
Synchrotron site | APS |
Beamline | 19-BM |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2016-06-15 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 0.97 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 102.805, 58.016, 87.854 |
Unit cell angles | 90.00, 103.01, 90.00 |
Refinement procedure
Resolution | 19.761 - 1.997 |
R-factor | 0.2304 |
Rwork | 0.228 |
R-free | 0.26840 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4xi3 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.555 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.030 |
High resolution limit [Å] | 1.997 | 2.000 |
Number of reflections | 34199 | |
<I/σ(I)> | 1.82 | |
Completeness [%] | 99.6 | |
Redundancy | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298.15 | 15% PEG 3,350, HEPES pH 6.5, 200 mM MgCl2 |