6AOD
FXIa antibody complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-07-29 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.03316 |
Spacegroup name | I 4 2 2 |
Unit cell lengths | 136.127, 136.127, 175.956 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 107.900 - 1.800 |
R-factor | 0.18315 |
Rwork | 0.182 |
R-free | 0.20680 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4kmt |
RMSD bond length | 0.025 |
RMSD bond angle | 2.059 |
Data scaling software | XDS (1) |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 107.980 | |
High resolution limit [Å] | 1.800 | 1.800 |
Rmerge | 2.663 | |
Number of reflections | 76265 | |
<I/σ(I)> | 13.99 | |
Completeness [%] | 99.0 | |
Redundancy | 8.9 | |
CC(1/2) | 0.244 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 1.86 M ammonium sulfate, 8 mM CoCl2, 30 mM K/Na phosphate, pH 6.5 |