6MPX
Twelve chloride ions induce formation and stabilize the NC1 hexamer of collagen IV assembled from transition state trimers
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-G |
| Synchrotron site | APS |
| Beamline | 21-ID-G |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2018-03-16 |
| Detector | RAYONIX MX-300 |
| Wavelength(s) | 0.9786 |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 121.160, 121.160, 106.020 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 39.893 - 1.900 |
| R-factor | 0.1492 |
| Rwork | 0.148 |
| R-free | 0.17670 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1li1 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA (3.3.22) |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.13_2998) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 85.673 | 40.387 | 2.000 |
| High resolution limit [Å] | 1.900 | 6.010 | 1.900 |
| Rmerge | 0.061 | 0.443 | |
| Rmeas | 0.129 | 0.065 | 0.470 |
| Rpim | 0.041 | 0.021 | 0.154 |
| Total number of observations | 558146 | ||
| Number of reflections | 62515 | 2152 | 9000 |
| <I/σ(I)> | 9.5 | 9.8 | 1.7 |
| Completeness [%] | 99.9 | 98.7 | 100 |
| Redundancy | 8.9 | 8.1 | 9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | .085 M HEPES (pH 7.5), 1.68 M ammonium sulfate, and 1.5% (w/v) PEG 400 |