6MAK
HBO1 is required for the maintenance of leukaemia stem cells
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-03-02 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.953736 |
| Spacegroup name | I 1 2 1 |
| Unit cell lengths | 87.628, 39.026, 107.765 |
| Unit cell angles | 90.00, 99.59, 90.00 |
Refinement procedure
| Resolution | 43.200 - 2.130 |
| R-factor | 0.21629 |
| Rwork | 0.214 |
| R-free | 0.26434 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.204 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0230) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 43.200 | 2.190 |
| High resolution limit [Å] | 2.130 | 2.130 |
| Rmerge | 0.070 | 0.748 |
| Rpim | 0.029 | 0.310 |
| Number of reflections | 19938 | 1558 |
| <I/σ(I)> | 13.1 | 2.6 |
| Completeness [%] | 98.0 | 94.2 |
| Redundancy | 6.9 | 6.6 |
| CC(1/2) | 0.998 | 0.882 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | Protein at 2.5 mg/mL was added in equal volume ratio with reservoir, 200 nL plus 200 nL. The reservoir consisted of 22% PEG MME 2000 plus 57 mM diammonium tartrate. Plates were stored at 20 C. |