6E56
Human antibody H2214 in complex with influenza hemagglutinin A/Aichi/2/1968 (X-31) (H3N2)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-02-23 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.97918 |
Spacegroup name | P 21 2 21 |
Unit cell lengths | 77.550, 98.710, 224.870 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.851 - 2.000 |
R-factor | 0.189 |
Rwork | 0.188 |
R-free | 0.21440 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | PDB entries 6B0A 4fp8 5y11 4yk4 |
RMSD bond length | 0.004 |
RMSD bond angle | 0.652 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((1.13_2998: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.851 | 2.072 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.106 | 0.121 |
Number of reflections | 117279 | 66956 |
<I/σ(I)> | 10.67 | 1.45 |
Completeness [%] | 99.4 | 99.92 |
Redundancy | 5.6 | 5.8 |
CC(1/2) | 0.997 | 0.544 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5 | 291.15 | 100 mM sodium chloride, 100 mM sodium acetate, pH 5.0, 20% w/v PEG2000 MME |