FXIa antibody complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-B
Synchrotron siteAPS
Beamline23-ID-B
Temperature [K]100
Detector technologyPIXEL
Collection date2015-07-29
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.03316
Spacegroup nameI 4 2 2
Unit cell lengths136.127, 136.127, 175.956
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution107.900 - 1.800
R-factor0.18315
Rwork0.182
R-free0.20680
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4kmt
RMSD bond length0.025
RMSD bond angle2.059
Data scaling softwareXDS (1)
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]107.980
High resolution limit [Å]1.8001.800
Rmerge2.663
Number of reflections76265
<I/σ(I)>13.99
Completeness [%]99.0
Redundancy8.9
CC(1/2)0.244
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2771.86 M ammonium sulfate, 8 mM CoCl2, 30 mM K/Na phosphate, pH 6.5

219869

PDB entries from 2024-05-15