Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5LLI

pVHL:EloB:EloC in complex with VH298

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2015-09-21
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9282
Spacegroup nameP 41 2 2
Unit cell lengths94.643, 94.643, 368.582
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.550 - 2.400
R-factor0.199
Rwork0.196
R-free0.25210
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1vcb
RMSD bond length0.009
RMSD bond angle1.327
Data reduction softwareXDS
Data scaling softwareAimless (0.3.11)
Phasing softwareREFMAC (5.8.0073)
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]49.55049.5502.460
High resolution limit [Å]2.40011.2602.400
Rmerge0.0990.0260.850
Number of reflections66540
<I/σ(I)>12.537.12.3
Completeness [%]99.698.999.5
Redundancy6.65.97
CC(1/2)0.9991.0000.804
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.4291PEG 3350, MgOAc, Sodium cacodylate, DTT

222926

PDB entries from 2024-07-24