5L7E
MCR IN COMPLEX WITH ligand
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-03-11 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.971 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 48.620, 77.830, 78.650 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 41.350 - 1.860 |
R-factor | 0.1807 |
Rwork | 0.180 |
R-free | 0.19730 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 0.960 |
Data reduction software | XDS |
Data scaling software | SCALA |
Refinement software | BUSTER (2.11.1 PACIOREK) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 1.860 |
Rmerge | 0.071 |
Number of reflections | 25505 |
<I/σ(I)> | 15.1 |
Completeness [%] | 99.0 |
Redundancy | 5.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 293 | 1.6 M AMS 0.1 M CHES pH 9.5 15% EG 10% Morpheus F12 |