5JDO
T. congolense haptoglobin-haemoglobin receptor in complex with haemoglobin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I03 |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-02-24 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.0000 |
Spacegroup name | P 2 21 21 |
Unit cell lengths | 72.750, 127.300, 172.420 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 102.410 - 3.200 |
R-factor | 0.206 |
Rwork | 0.204 |
R-free | 0.23510 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4E40 and 1HH0 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.210 |
Data reduction software | iMOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.2) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 102.410 |
High resolution limit [Å] | 3.200 |
Rpim | 0.073 |
Number of reflections | 26536 |
<I/σ(I)> | 7.3 |
Completeness [%] | 99.0 |
Redundancy | 2.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 0.1 M sodium citrate pH 5, 8% w/v PEG 8000 |