5GGS
PD-1 in complex with pembrolizumab Fab
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 7A (6B, 6C1) |
Synchrotron site | PAL/PLS |
Beamline | 7A (6B, 6C1) |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-06-05 |
Detector | ADSC QUANTUM 270 |
Wavelength(s) | 1 |
Spacegroup name | P 1 |
Unit cell lengths | 54.170, 54.195, 104.039 |
Unit cell angles | 105.69, 96.99, 96.06 |
Refinement procedure
Resolution | 30.038 - 1.997 |
R-factor | 0.1819 |
Rwork | 0.179 |
R-free | 0.22800 |
RMSD bond length | 0.008 |
RMSD bond angle | 1.165 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 1.990 |
Number of reflections | 71844 |
<I/σ(I)> | 20.1 |
Completeness [%] | 95.2 |
Redundancy | 1.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MES, pH 6.5, 12% PEG500 MME, 6% PEG20,000, 50 mM ammonium acetate |