5FMJ
Bcl-xL with mouse Bak BH3 Q75L complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-02-11 |
Detector | ADSC QUANTUM 315r |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 57.789, 57.789, 268.327 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 19.662 - 2.430 |
R-factor | 0.1819 |
Rwork | 0.180 |
R-free | 0.21950 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2p1l |
RMSD bond length | 0.009 |
RMSD bond angle | 0.935 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.660 | 2.670 |
High resolution limit [Å] | 2.430 | 2.430 |
Rmerge | 0.080 | 0.760 |
Number of reflections | 10808 | |
<I/σ(I)> | 27.6 | 3.8 |
Completeness [%] | 99.3 | 98.3 |
Redundancy | 19.2 | 14.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 0.2 M SODIUM THIOCYANATE, 20% PEG 3350 |