5FC6
Murine SMPDL3A in complex with ADP analog AMPCP
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CLSI BEAMLINE 08ID-1 |
| Synchrotron site | CLSI |
| Beamline | 08ID-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-01-21 |
| Detector | RAYONIX MX-300 |
| Wavelength(s) | 0.97949 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 124.351, 132.888, 80.519 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 45.399 - 1.658 |
| R-factor | 0.1625 |
| Rwork | 0.161 |
| R-free | 0.19070 |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.083 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 45.400 |
| High resolution limit [Å] | 1.658 |
| Number of reflections | 78590 |
| <I/σ(I)> | 15.8 |
| Completeness [%] | 99.6 |
| Redundancy | 7.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | citrate, PEG |