Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5C6W

anti-CXCL13 scFv - E10

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]193
Detector technologyPIXEL
Collection date2012-11-29
DetectorPSI PILATUS 6M
Wavelength(s)1.0
Spacegroup nameP 21 21 21
Unit cell lengths69.980, 80.360, 119.240
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution50.000 - 1.540
R-factor0.1544
Rwork0.154
R-free0.16350
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3juy
RMSD bond length0.010
RMSD bond angle1.090
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareBUSTER (2.11.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.630
High resolution limit [Å]1.5401.540
Rmerge0.0440.496
Number of reflections98395
<I/σ(I)>263.4
Completeness [%]98.892.2
Redundancy8.86.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.5291100 mM Tris pH 8.5, 2000 mM (NH4)2SO4

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon