5C53
Probing the Structural and Molecular Basis of Nucleotide Selectivity by Human Mitochondrial DNA Polymerase gamma
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.2.1 |
| Synchrotron site | ALS |
| Beamline | 8.2.1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-08-01 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 217.447, 217.447, 163.593 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.909 - 3.567 |
| R-factor | 0.3014 |
| Rwork | 0.300 |
| R-free | 0.33820 |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.751 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 3.620 |
| Number of reflections | 47258 |
| <I/σ(I)> | 2 |
| Completeness [%] | 100.0 |
| Redundancy | 7.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 300 | PEG4000, KCl, HEPES |