Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5C09

HLA class I histocompatibility antigen

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyPIXEL
Collection date2012-03-08
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97630
Spacegroup nameP 1
Unit cell lengths43.830, 100.070, 122.440
Unit cell angles96.91, 98.31, 96.52
Refinement procedure
Resolution98.457 - 2.475
R-factor0.2074
Rwork0.205
R-free0.25880
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3UTP and 3UTQ
RMSD bond length0.013
RMSD bond angle1.743
Data reduction softwareXDS
Data scaling softwareSCALA (3.3.20)
Phasing softwarePHASER (2.1.4)
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]98.45798.4572.540
High resolution limit [Å]2.47511.0702.470
Rmerge0.0740.563
Rmeas0.127
Rpim0.0840.0430.407
Total number of observations140157163310379
Number of reflections70968
<I/σ(I)>4.97.82.1
Completeness [%]98.296.897.5
Redundancy22.12
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2910.1M sodium cacodylate pH6.5, 15% PEG 4000, 0.2M sodium acetate

218500

PDB entries from 2024-04-17

PDB statisticsPDBj update infoContact PDBjnumon