5BK8
Cancer-associated SHP2/T507K mutant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-04-01 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.97857 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 54.699, 203.176, 44.366 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.658 - 2.250 |
R-factor | 0.2014 |
Rwork | 0.198 |
R-free | 0.26200 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4dgp |
RMSD bond length | 0.008 |
RMSD bond angle | 1.005 |
Data reduction software | HKL-3000 |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.290 |
High resolution limit [Å] | 2.250 | 2.250 |
Rmerge | 0.140 | 0.811 |
Total number of observations | 105858 | |
Number of reflections | 23674 | 1139 |
<I/σ(I)> | 12.66 | 1.487 |
Completeness [%] | 95.7 | 93.8 |
Redundancy | 4.5 | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 16% PEG3350, 200 mM LiCl |