5Y9E
Crystal structure of HPV58 pentamer
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U1 |
Synchrotron site | SSRF |
Beamline | BL17U1 |
Temperature [K] | 80 |
Detector technology | CCD |
Collection date | 2014-09-10 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9792 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 187.213, 101.804, 136.195 |
Unit cell angles | 90.00, 95.68, 90.00 |
Refinement procedure
Resolution | 29.781 - 2.042 |
R-factor | 0.1707 |
Rwork | 0.168 |
R-free | 0.19830 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.525 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.11.1_2575)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 30.000 |
High resolution limit [Å] | 2.040 |
Number of reflections | 159674 |
<I/σ(I)> | 19.6 |
Completeness [%] | 99.2 |
Redundancy | 7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.2 M magnesium formate, 14.5% (w/v) PEG 3350 |