5VLA
Short PCSK9 delta-P' complex with Fusion2 peptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.1 |
| Synchrotron site | ALS |
| Beamline | 5.0.1 |
| Temperature [K] | 110 |
| Detector technology | CCD |
| Collection date | 2015-08-15 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.97741 |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 70.267, 70.267, 157.254 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 26.310 - 2.400 |
| R-factor | 0.211 |
| Rwork | 0.209 |
| R-free | 0.26700 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4nmx |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.060 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | BUSTER (2.11.6) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 26.310 | 2.480 |
| High resolution limit [Å] | 2.400 | 2.400 |
| Number of reflections | 16868 | |
| <I/σ(I)> | 22.3 | 5.4 |
| Completeness [%] | 92.1 | 100 |
| Redundancy | 7.6 | 7.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8 | 292 | calcium acetate, PEG 6000 |