5FLF
DISEASE LINKED MUTATION IN FGFR
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04 |
| Synchrotron site | Diamond |
| Beamline | I04 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2015-09-14 |
| Detector | DECTRIS PILATUS 6M |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 76.259, 152.281, 195.887 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 71.064 - 2.580 |
| R-factor | 0.1967 |
| Rwork | 0.194 |
| R-free | 0.25450 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4uwy |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.752 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 76.260 | 2.640 |
| High resolution limit [Å] | 2.580 | 2.580 |
| Rmerge | 0.100 | 0.600 |
| Number of reflections | 70919 | |
| <I/σ(I)> | 10.4 | 1.5 |
| Completeness [%] | 98.2 | 97.2 |
| Redundancy | 4.1 | 3.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 7.5 | 20 PEG 400, 0.75 M AMMONIUM SULPHATE, 0.1 M MAGNESIUM CHLORIDE, 0.1 M HEPES PH 7.5 |