Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4ZJR

RORgamma in complex with inverse agonist 48

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyCCD
Collection date2014-11-10
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.98
Spacegroup nameP 31
Unit cell lengths98.409, 98.409, 129.752
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution85.220 - 2.702
R-factor0.1759
Rwork0.173
R-free0.22270
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3b0w
RMSD bond length0.015
RMSD bond angle1.840
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0107)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]85.22519.9962.420
High resolution limit [Å]2.3007.2702.300
Rmerge0.1110.0965.130
Rmeas0.233
Rpim0.085
Total number of observations66280264042
Number of reflections38506
<I/σ(I)>15.33.10.3
Completeness [%]99.794.699.5
Redundancy7.46.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP82981.0M Sodium Acetate, 0.2M Sodium Chloride, 0.1M TRIS pH 8.0

225681

PDB entries from 2024-10-02

PDB statisticsPDBj update infoContact PDBjnumon