4XAR
mGluR2 ECD and mGluR3 ECD complex with ligands
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 31-ID |
| Synchrotron site | APS |
| Beamline | 31-ID |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-02-28 |
| Detector | RAYONIX MX-225 |
| Wavelength(s) | 0.97931 |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 80.338, 80.338, 155.688 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 37.680 - 2.260 |
| R-factor | 0.1979 |
| Rwork | 0.197 |
| R-free | 0.22410 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.070 |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | BUSTER-TNT (BUSTER 2.11.5) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 37.680 |
| High resolution limit [Å] | 2.260 |
| Number of reflections | 27749 |
| <I/σ(I)> | 8.2 |
| Completeness [%] | 99.0 |
| Redundancy | 10.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 295 | 20% PEG 3350, 200mM Ammonium Iodide |