Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X25 |
Synchrotron site | NSLS |
Beamline | X25 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2011-04-02 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1.1000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 209.630, 449.300, 620.900 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.713 - 2.700 |
R-factor | 0.2188 |
Rwork | 0.217 |
R-free | 0.25430 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.013 |
RMSD bond angle | 1.500 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHENIX |
Refinement software | PHENIX (1.7.2_869) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 49.713 | 49.713 | 2.770 |
High resolution limit [Å] | 2.700 | 12.070 | 2.700 |
Rmerge | 0.166 | 0.018 | 0.018 |
Number of reflections | 1562621 | ||
<I/σ(I)> | 10.89 | 51.46 | 0.82 |
Completeness [%] | 98.7 | 97.9 | 94.5 |
Redundancy | 7.57 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7.6 | 292 | 0.1-0.2M Arginine-HCl, 0.1M Tris-HCl pH 7.6, 2.5% PEG-20K, 7-12% MPD, 0.5mM BME, VAPOR DIFFUSION, temperature 292K |