4UUZ
MCM2-histone complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SOLEIL BEAMLINE PROXIMA 1 |
| Synchrotron site | SOLEIL |
| Beamline | PROXIMA 1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2014-07-05 |
| Detector | DECTRIS PILATUS 6M |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 140.090, 140.090, 65.870 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 57.890 - 2.900 |
| R-factor | 0.199 |
| R-free | 0.23030 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1kx5 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.150 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | MOLREP |
| Refinement software | BUSTER (2.11.5) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 60.000 | 2.970 |
| High resolution limit [Å] | 2.900 | 2.900 |
| Rmerge | 0.080 | 1.500 |
| Number of reflections | 5602 | |
| <I/σ(I)> | 19.7 | 1.2 |
| Completeness [%] | 99.9 | 98.8 |
| Redundancy | 10.8 | 10.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 0.1M HEPES PH7, 21% PEG3000 |