4UE7
Thrombin in complex with 1-amidinopiperidine
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 113 |
Detector technology | CCD |
Collection date | 2013-07-18 |
Detector | MARMOSAIC 225 mm CCD |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 70.262, 71.483, 72.440 |
Unit cell angles | 90.00, 100.30, 90.00 |
Refinement procedure
Resolution | 19.563 - 1.129 |
R-factor | 0.1243 |
Rwork | 0.123 |
R-free | 0.13940 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1h8d |
RMSD bond length | 0.010 |
RMSD bond angle | 1.449 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.560 | 1.150 |
High resolution limit [Å] | 1.130 | 1.130 |
Rmerge | 0.040 | 0.390 |
Number of reflections | 130988 | |
<I/σ(I)> | 24.5 | 2.54 |
Completeness [%] | 99.5 | 99.5 |
Redundancy | 3 | 2.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.5 | SEE MATERIALS AND METHODS SECTION OF PUBLICATION, pH 7.5 |