4O3U
Zymogen HGF-beta/MET with Zymogen Activator Peptide ZAP2.3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL12-2 |
Synchrotron site | SSRL |
Beamline | BL12-2 |
Temperature [K] | 110 |
Detector technology | PIXEL |
Collection date | 2012-05-23 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 0.9794 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 136.105, 139.620, 66.144 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 34.760 - 3.040 |
R-factor | 0.2087 |
Rwork | 0.207 |
R-free | 0.25070 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1shy |
RMSD bond length | 0.009 |
RMSD bond angle | 1.240 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.2) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 34.760 |
High resolution limit [Å] | 3.040 |
Number of reflections | 24340 |
<I/σ(I)> | 23 |
Completeness [%] | 97.5 |
Redundancy | 6.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.2 | 293 | 8% PEG8000, pH 7.2, VAPOR DIFFUSION, SITTING DROP, temperature 293K |