4NE9
PCSK9 in complex with LDLR peptide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2012-01-01 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 126.398, 131.392, 134.634 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.020 - 2.600 |
R-factor | 0.1911 |
Rwork | 0.190 |
R-free | 0.21140 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.160 |
Refinement software | BUSTER (2.11.5) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 94.000 | 2.760 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.075 | 0.853 |
Number of reflections | 66485 | |
<I/σ(I)> | 23 | 3.4 |
Completeness [%] | 95.5 | 86.2 |
Redundancy | 6.2 | 6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 299 | pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 299K |