4NCT

Human DYRK1A in complex with PKC412

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2013-10-19
DetectorPSI PILATUS 6M
Wavelength(s)0.918409
Spacegroup nameP 21 21 21
Unit cell lengths87.764, 87.895, 229.921
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.250 - 2.597
R-factor0.2101
Rwork0.208
R-free0.24946
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle1.110
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0032)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]48.2504.4802.750
High resolution limit [Å]2.5973.8902.597
Number of reflections55625
Completeness [%]99.799.898.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.82930.1 M KSCN; 0.05M LiCl; 10% PEG 3350, pH 6.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K