Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4MJP

E. coli sliding clamp in complex with (R)-Vedaprofen

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2013-07-20
DetectorMAR scanner 345 mm plate
Wavelength(s)1.5418
Spacegroup nameP 1 21 1
Unit cell lengths79.711, 66.950, 81.045
Unit cell angles90.00, 113.51, 90.00
Refinement procedure
Resolution28.590 - 1.855
R-factor0.1937
Rwork0.192
R-free0.23700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1mmi
RMSD bond length0.007
RMSD bond angle1.221
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]30.00030.0001.920
High resolution limit [Å]1.8553.9801.855
Rmerge0.0360.0270.304
Number of reflections64553
<I/σ(I)>21.8
Completeness [%]96.194.381.8
Redundancy2.72.82.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5285100mM MES, 100-150mM CaCl2, 25-30%(v/v) PEG400, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 285K

223532

PDB entries from 2024-08-07

PDB statisticsPDBj update infoContact PDBjnumon