4JKP
Restricting HIV-1 Pathways for Escape using Rationally-Designed Anti-HIV-1 Antibodies
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL12-2 |
Synchrotron site | SSRL |
Beamline | BL12-2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2012-03-16 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9537 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 69.330, 70.490, 232.220 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 34.846 - 2.820 |
R-factor | 0.1953 |
Rwork | 0.193 |
R-free | 0.23100 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.027 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: dev_1026)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 34.850 | 2.890 |
High resolution limit [Å] | 2.820 | 2.820 |
Number of reflections | 27846 | |
Completeness [%] | 98.4 | 99.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5 | 293 | 12% (v/v) isopropanol, 10% (w/v) polyethylene glycol 10,000 kD, 0.1 M citrate , pH 5.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K |