3TZ7
Kinase domain of cSrc in complex with RL103
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | BRUKER AXS MICROSTAR |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2009-05-21 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.541700 |
Spacegroup name | P 1 |
Unit cell lengths | 42.550, 64.280, 75.400 |
Unit cell angles | 79.28, 87.38, 90.20 |
Refinement procedure
Resolution | 28.580 - 3.300 |
R-factor | 0.193 |
Rwork | 0.189 |
R-free | 0.25630 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3f3v |
RMSD bond length | 0.009 |
RMSD bond angle | 1.224 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER (1.3.1) |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 40.000 | 40.000 | 3.400 |
High resolution limit [Å] | 3.300 | 16.000 | 3.300 |
Rmerge | 0.063 | 0.020 | 0.171 |
Rmeas | 0.027 | 0.234 | |
Number of reflections | 11298 | 78 | 954 |
<I/σ(I)> | 15.24 | 38.45 | 5.64 |
Completeness [%] | 95.8 | 75 | 95.6 |
Redundancy | 2.21 | 2.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | 10% PEG 20000, 15% glycerol, 100mM MES, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |