Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyCCD
Collection date2009-11-26
DetectorX-flash
Wavelength(s)0.91841
Spacegroup nameI 2 3
Unit cell lengths229.640, 229.640, 229.640
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.838 - 3.102
R-factor0.1904
Rwork0.188
R-free0.22690
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3mqi
RMSD bond length0.005
RMSD bond angle0.837
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.5_2))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.000
High resolution limit [Å]3.1003.100
Rmerge0.0680.700
Number of reflections36262
<I/σ(I)>20.12.55
Completeness [%]20.0
Redundancy55.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.62772.9M sodium chloride 0.1M BTP, pH 6.6, VAPOR DIFFUSION, HANGING DROP, temperature 277K

227111