3JTC
Importance of Mg2+ in the Ca2+-Dependent Folding of the gamma-Carboxyglutamic Acid Domains of Vitamin K-Dependent clotting and anticlotting Proteins
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU300 |
Temperature [K] | 110 |
Detector technology | IMAGE PLATE |
Collection date | 2001-04-25 |
Detector | MARRESEARCH |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 59.220, 62.360, 71.030 |
Unit cell angles | 90.00, 101.81, 90.00 |
Refinement procedure
Resolution | 23.220 - 1.600 |
R-factor | 0.19246 |
Rwork | 0.191 |
R-free | 0.22648 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 1.450 |
RMSD bond angle | 2.566 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.610 |
High resolution limit [Å] | 1.550 | 1.550 |
Rmerge | 0.455 | |
Number of reflections | 66375 | |
<I/σ(I)> | 27 | 27 |
Completeness [%] | 90.1 | 91 |
Redundancy | 4 | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7 | PEG 400, potassium chloride, magnesium chloride, calcium chloride, HEPES, PH 7.0, VAPOR DIFFUSION |