Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3IK9

Human GST A1-1-GIMF with GSDHN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL11-1
Synchrotron siteSSRL
BeamlineBL11-1
Temperature [K]100
Detector technologyCCD
Collection date2009-01-29
DetectorMARMOSAIC 325 mm CCD
Wavelength(s)0.98
Spacegroup nameP 1 21 1
Unit cell lengths95.889, 114.658, 96.239
Unit cell angles90.00, 117.76, 90.00
Refinement procedure
Resolution39.920 - 2.200
R-factor0.226
Rwork0.224
R-free0.27900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1k3y
RMSD bond length0.011
RMSD bond angle1.300
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareBALBES
Refinement softwareREFMAC (5.5.0047)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.180
High resolution limit [Å]2.1002.100
Rmerge0.1070.701
Number of reflections97225
<I/σ(I)>12.649
Completeness [%]89.661.6
Redundancy4.52.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529816% PEG mme 5000, 0.1 M HEPES, pH 7.5, and 10% isopropanol, VAPOR DIFFUSION, SITTING DROP, temperature 298K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon