3F73
Alignment of guide-target seed duplex within an argonaute silencing complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2008-01-01 |
Detector | MAR scanner 300 mm plate |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 61.162, 120.527, 109.085 |
Unit cell angles | 90.00, 105.30, 90.00 |
Refinement procedure
Resolution | 30.000 - 3.000 |
R-factor | 0.221 |
Rwork | 0.221 |
R-free | 0.28200 |
Starting model (for MR) | 3dlh |
RMSD bond length | 0.009 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASES |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.110 |
High resolution limit [Å] | 3.000 | 3.000 |
Rmerge | 0.390 | |
Number of reflections | 29830 | |
<I/σ(I)> | 15.8 | 2.1 |
Completeness [%] | 99.4 | |
Redundancy | 4.2 | 3.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 5.6 | 308 | 10% (v/v) PEG400, 50mM Mes 5.6, 0.1M KCl, 15 mM MgCl2, VAPOR DIFFUSION, HANGING DROP, temperature 308K |
Crystallization Reagents
ID | crystal ID | solution ID | reagent name | concentration | details |
1 | 1 | 1 | PEG 400 | ||
2 | 1 | 1 | MES | ||
3 | 1 | 1 | KCL | ||
4 | 1 | 1 | MgCl2 | ||
5 | 1 | 2 | PEG 400 | ||
6 | 1 | 2 | MES | ||
7 | 1 | 2 | KCl | ||
8 | 1 | 2 | MgCl2 |