Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL26B2 |
Synchrotron site | SPring-8 |
Beamline | BL26B2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-11-14 |
Detector | MARRESEARCH |
Wavelength(s) | 0.9790, 0.9793, 0.9640 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 74.506, 74.506, 146.524 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 48.840 - 2.100 |
R-factor | 0.1999 |
Rwork | 0.199 |
R-free | 0.22529 |
Structure solution method | MAD |
RMSD bond length | 0.020 |
RMSD bond angle | 1.723 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SOLVE |
Refinement software | REFMAC (5.1.24) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.180 |
High resolution limit [Å] | 2.100 | 2.100 |
Number of reflections | 28345 | |
<I/σ(I)> | 21.1476 | 4.223 |
Completeness [%] | 99.9 | 99.4 |
Redundancy | 9.882 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293 | Ammonium sulfate, PEG, pH 5.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K |