2ESL
Human Cyclophilin C in Complex with Cyclosporin A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-BM |
Synchrotron site | APS |
Beamline | 19-BM |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2005-06-29 |
Detector | SBC-3 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 72.203, 123.802, 135.250 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 36.400 - 1.900 |
R-factor | 0.18 |
Rwork | 0.178 |
R-free | 0.22500 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 1.373 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 36.400 | 1.970 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.078 | 0.515 |
Number of reflections | 95283 | |
<I/σ(I)> | 25.5 | 3.68 |
Completeness [%] | 98.6 | 97.8 |
Redundancy | 7 | 7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 6.5 | 25% PEG550 MME, 10MM ZINC ACETATE, 100MM MES, PH 6.5, VAPOR DIFFUSION, SITTING DROP, TEMPERATURE 298.0K |