2R2M
2-(2-Chloro-6-Fluorophenyl)Acetamides as Potent Thrombin Inhibitors
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS FR591 |
Detector technology | IMAGE PLATE |
Collection date | 2001-03-06 |
Detector | RIGAKU RAXIS II |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 70.950, 72.135, 72.850 |
Unit cell angles | 90.00, 100.64, 90.00 |
Refinement procedure
Resolution | 20.000 - 2.100 |
Rwork | 0.168 |
R-free | 0.21400 |
RMSD bond length | 0.004 |
RMSD bond angle | 0.599 |
Phasing software | X-PLOR |
Refinement software | PHENIX |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 20.000 |
High resolution limit [Å] | 2.100 |
Number of reflections | 18902 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |