1YK7
Cathepsin K complexed with a cyanopyrrolidine inhibitor
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU |
| Temperature [K] | 93 |
| Detector technology | IMAGE PLATE |
| Collection date | 1999-03-15 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 32.241, 66.653, 93.187 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 20.000 - 2.500 |
| Rwork | 0.190 |
| R-free | 0.27000 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1q6k |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.200 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 2.660 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Rmerge | 0.150 | 0.310 |
| Number of reflections | 7079 | |
| <I/σ(I)> | 26 | 10.8 |
| Completeness [%] | 96.7 | 84.4 |
| Redundancy | 7.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | 0.2 M ammonium sulfate, 30% PEG8000, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |