1W78
E.coli FolC in complex with DHPP and ADP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2000-11-06 |
Detector | MACSCIENCE DIP2000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 64.368, 80.620, 92.829 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 25.000 - 1.820 |
Rwork | 0.165 |
R-free | 0.20300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1jbv |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | AMoRE |
Refinement software | BUSTER |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 25.000 | 1.920 |
High resolution limit [Å] | 1.820 | 1.820 |
Rmerge | 0.070 | 0.280 |
Number of reflections | 42097 | |
<I/σ(I)> | 12.3 | 3.7 |
Completeness [%] | 96.4 | 88.7 |
Redundancy | 3.3 | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 8.7 | 1.5 M AMMONIUM SULFATE 5 MM DTT 50 MM BICINE PH 8.7 |