1LWG

Multiple Methionine Substitutions are Tolerated in T4 Lysozyme and have Coupled Effects on Folding and Stability

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL9-1
Synchrotron siteSSRL
BeamlineBL9-1
Temperature [K]173
Detector technologyIMAGE PLATE
Collection date2002-02-10
DetectorMARRESEARCH
Wavelength(s)0.77487
Spacegroup nameP 32 2 1
Unit cell lengths60.425, 60.425, 90.388
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution19.800 - 1.700
R-factor0.194
Rwork0.194
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1l63
RMSD bond length0.019
RMSD bond angle2.844
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Refinement softwareTNT
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]19.8001.790
High resolution limit [Å]1.7001.700
Rmerge0.0520.284
Number of reflections21345
<I/σ(I)>7.12.7
Completeness [%]99.496.8
Redundancy3.33.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROPVAPOR DIFFUSION, HANGING DROP

240971