1G30
THROMBIN INHIBITOR COMPLEX
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 1997-09-01 |
Detector | MARRESEARCH |
Wavelength(s) | 1.54 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 69.300, 70.900, 72.800 |
Unit cell angles | 90.00, 100.30, 90.00 |
Refinement procedure
Resolution | 15.980 - 2.000 |
R-factor | 0.21 * |
Rwork | 0.210 |
R-free | 0.26400 |
Structure solution method | FOURIER SYNTHESIS |
RMSD bond length | 0.008 |
RMSD bond angle | 1.760 * |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | X-PLOR |
Refinement software | CNX (2000) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 15.800 |
High resolution limit [Å] | 2.000 |
Rmerge | 0.055 |
Total number of observations | 53146 * |
Number of reflections | 22489 |
<I/σ(I)> | 10 |
Completeness [%] | 94.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | other * | Skrzypczak-Jankun, E., (1991) J. Mol. Biol., 221, 1379. * |