1W63

AP1 clathrin adaptor core

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCHESS BEAMLINE F1
Synchrotron siteCHESS
BeamlineF1
Temperature [K]100
Detector technologyCCD
DetectorADSC CCD
Spacegroup nameP 32 1 2
Unit cell lengths178.140, 178.140, 1134.994
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution40.000 - 4.000
R-factor0.2972
Rwork0.297
R-free0.30970
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1GW5
RMSD bond length0.014
RMSD bond angle1.861
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareCNS (1.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.8404.100
High resolution limit [Å]4.0104.000
Rmerge0.1200.470
Number of reflections141015
<I/σ(I)>9.42.5
Completeness [%]81.369.7
Redundancy6.54.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
178-9% ETHANOL, 0.1 M NA HEPES, PH 7.5, 2 MM CYSTEINE

219869