Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9TOS

Drop on fixed target room temperature serial crystal structure of hen egg white lysozyme, drop on fixed target at DLS, 1.9 s checkerboard control (N-acetyl glucosamine).

Summary for 9TOS
Entry DOI10.2210/pdb9tos/pdb
DescriptorLysozyme C, CHLORIDE ION, SODIUM ION, ... (4 entities in total)
Functional Keywordslysozyme, serial, room temperature, hydrolase
Biological sourceGallus gallus (chicken)
Total number of polymer chains1
Total formula weight14495.96
Authors
Hinchliffe, P.,Kamps, J.A.G.,Aller, P.,Orville, A.M. (deposition date: 2025-12-17, release date: 2026-06-17)
Primary citationKamps, J.J.A.G.,Hinchliffe, P.,Glerup, J.,Freeman, E.I.,Lang, P.A.,Tooke, C.L.,Beer, M.,Parkinson, L.,Gu, D.H.,Park, S.,Devenish, N.,Zhou, T.,Shilova, A.,Kaur, S.,Rabe, P.,Schofield, C.J.,Spencer, J.,Park, J.,Owen, R.L.,Orville, A.M.,Aller, P.
Drop-on-fixed-target reaction initiation approach for serial and time-resolved crystallography.
Iucrj, 2026
Cited by
PubMed Abstract: We describe the design and implementation of a drop-on-fixed-target method for time-resolved serial crystallography at both synchrotron and XFEL facilities. A piezoelectric droplet dispensing pipette is employed for addition of picolitre volume aqueous droplets (∼40-90 pl; ∼40-55 µm diameter sphere), containing (co-)substrate(s) or ligand(s), onto enzyme microcrystals previously loaded into the trapezoidal wells of an etched crystalline silicon fixed-target chip containing 25 600 wells in a high-density, square grid with 125 µm centre-to-centre well spacing. These features demand exquisite accuracy and thereby constrain motion controls to enable robust time-resolved crystallographic studies. The system was tested with three enzyme systems, comprising lysozyme and two β-lactamases, CTX-M-15 and AmpC. Mitigation strategies for cross-well contamination, including the implementation of interleaved controls, are described; the overall performance of the system at synchrotron and X-ray free-electron laser facilities was evaluated. This drop-on-fixed-target method is a reliable framework for time-resolved crystallography and will improve the consistency of measurements across facilities.
PubMed: 42246252
DOI: 10.1107/S2052252526003489
PDB entries with the same primary citation
Experimental method
X-RAY DIFFRACTION (1.67 Å)
Structure validation

255615

PDB entries from 2026-06-24

PDB statisticsPDBj update infoContact PDBjnumon