2CCE
Parallel Configuration of pLI E20S
2CCE の概要
エントリーDOI | 10.2210/pdb2cce/pdb |
関連するPDBエントリー | 1CE9 1DGC 1ENV 1FAV 1GCL 1GCM 1GK6 1GZL 1IHQ 1IJ0 1IJ1 1IJ2 1IJ3 1KQL 1LD4 1LLM 1NKN 1PIQ 1RB1 1RB4 1RB5 1RB6 1SWI 1TMZ 1UNT 1UNU 1UNV 1UNW 1UNX 1UNY 1UNZ 1UO0 1UO1 1UO2 1UO3 1UO4 1UO5 1VZL 1W5G 1W5H 1W5I 1W5J 1W5K 1W5L 1YSA 1ZII 1ZIJ 1ZIK 1ZIL 1ZIM 1ZTA 2B1F 2B22 2BNI 2CCF 2CCN 2DGC 2ZTA |
分子名称 | General control protein GCN4 (2 entities in total) |
機能のキーワード | four helix bundle, antiparallel, parallel, pli, dna-binding, nuclear protein, transcription, transcription regulation, activator, amino-acid biosynthesis |
由来する生物種 | Saccharomyces cerevisiae (Baker's yeast) |
タンパク質・核酸の鎖数 | 2 |
化学式量合計 | 8061.60 |
構造登録者 | Yadav, M.K.,Leman, L.J.,Price, D.J.,Brooks 3rd, C.L.,Stout, C.D.,Ghadiri, M.R. (登録日: 2006-01-16, 公開日: 2006-04-06, 最終更新日: 2024-10-09) |
主引用文献 | Yadav, M.K.,Leman, L.J.,Price, D.J.,Brooks 3rd, C.L.,Stout, C.D.,Ghadiri, M.R. Coiled coils at the edge of configurational heterogeneity. Structural analyses of parallel and antiparallel homotetrameric coiled coils reveal configurational sensitivity to a single solvent-exposed amino acid substitution. Biochemistry, 45:4463-4473, 2006 Cited by PubMed Abstract: A detailed understanding of the mechanisms by which particular amino acid sequences can give rise to more than one folded structure, such as for proteins that undergo large conformational changes or misfolding, is a long-standing objective of protein chemistry. Here, we describe the crystal structures of a single coiled-coil peptide in distinct parallel and antiparallel tetrameric configurations and further describe the parallel or antiparallel crystal structures of several related peptide sequences; the antiparallel tetrameric assemblies represent the first crystal structures of GCN4-derived peptides exhibiting such a configuration. Intriguingly, substitution of a single solvent-exposed residue enabled the parallel coiled-coil tetramer GCN4-pLI to populate the antiparallel configuration, suggesting that the two configurations are close enough in energy for subtle sequence changes to have important structural consequences. We present a structural analysis of the small changes to the helix register and side-chain conformations that accommodate the two configurations and have supplemented these results using solution studies and a molecular dynamics energetic analysis using a replica exchange methodology. Considering the previous examples of structural nonspecificity in coiled-coil peptides, the findings reported here not only emphasize the predisposition of the coiled-coil motif to adopt multiple configurations but also call attention to the associated risk that observed crytstal structures may not represent the only (or even the major) species present in solution. PubMed: 16584182DOI: 10.1021/bi060092q 主引用文献が同じPDBエントリー |
実験手法 | X-RAY DIFFRACTION (1.9 Å) |
構造検証レポート
検証レポート(詳細版)をダウンロード